Keensen SW-8040 Seawater RO Membrane | 8040 SWRO HF / MR / HR Options
8" × 40" seawater reverse osmosis membrane elements for commercial and industrial SWRO systems, desalination, high-salinity feedwater treatment, RO concentrate reuse and selected high-salinity wastewater concentration applications.
The Keensen SW-8040 series is available for enquiry and supply to order, with HF, MR and HR options for different seawater RO design priorities. Final model selection should be reviewed against feedwater salinity, operating pressure, recovery rate, permeate quality target, pretreatment condition and existing SWRO system design.
Supply to order. Contact Crystwater for pricing, lead time and application review.
Please provide the existing membrane model, quantity, application, feed salinity or conductivity, operating pressure, required permeate quality and delivery postcode where available.
Product Overview
Specifications
| Membrane family | Keensen SW series |
|---|---|
| Membrane chemistry | Aromatic polyamide composite |
| Format | 8040 / 8" × 40" |
| Active membrane area | 400 ft² / 37.2 m² |
| Concentrate channel spacer | 28 mil |
| Model | Permeate flow | Stabilized salt rejection | Minimum salt rejection |
|---|---|---|---|
| SW-8040HF | 9,000 GPD / 34.1 m³/d | 99.80% | 99.70% |
| SW-8040MR | 7,500 GPD / 28.3 m³/d | 99.75% | 99.70% |
| SW-8040HR | 6,500 GPD / 24.6 m³/d | 99.80% | 99.75% |
Test Conditions
| Parameter | Test Condition |
|---|---|
| Test solution | 32,000 mg/L NaCl |
| Temperature | 25°C |
| pH | 7.5-8.0 |
| Operating pressure | 800 psi / 5.5 MPa |
| Recovery | 8% |
| Water production tolerance | ±15% |
Operating Limits
| Parameter | Limit |
|---|---|
| Maximum operating pressure | 1200 psi / 8.3 MPa |
| Maximum feed flow rate | 17.0 m³/h |
| Maximum operating temperature | 45°C |
| Maximum SDI15 | 5.0 |
| Free chlorine tolerance | 0.1 mg/L |
| Continuous operation pH range | 3-10 |
| Short-term cleaning pH range | 1-13 |
| Maximum element pressure drop | 15 psi / 0.1 MPa |
Selecting HF, MR or HR
Select SW-8040HF where higher permeate flow is the main design priority and system conditions allow. Select SW-8040MR where a balanced seawater RO option is suitable for the application. Select SW-8040HR where minimum salt rejection and permeate quality are prioritised.
For replacement enquiries, please provide the existing membrane model, quantity, feed salinity or conductivity, operating pressure, recovery rate, required permeate quality and delivery postcode.
Typical Applications
- Seawater desalination
- High-salinity source water treatment
- Commercial and industrial SWRO systems
- RO concentrate reuse
- High-salinity wastewater concentration
- Zero liquid discharge pretreatment or concentration applications
- Material concentration where SWRO membranes are suitable
Application suitability depends on feedwater quality, pretreatment, operating pressure, recovery rate, scaling risk, fouling risk and permeate quality requirements.
Supply, Lead Time & Freight
This product is supplied to order. Pricing and lead time are confirmed by quotation based on model selection, quantity, production availability, freight method, delivery location and current market conditions.
For bulk or project-based enquiries, Crystwater can provide pricing, estimated lead time and freight basis after the required model, quantity and delivery postcode are confirmed.
SWRO Membrane FAQs
Is this product in stock?
This SWRO membrane page is for enquiry and supply-to-order requests. Pricing and lead time are confirmed by quotation.
What is the difference between SW-8040HF, SW-8040MR and SW-8040HR?
SW-8040HF is positioned for higher permeate flow, SW-8040MR is a balanced seawater RO option, and SW-8040HR is positioned for higher minimum salt rejection and permeate quality priority.
Can this replace another 8040 seawater RO membrane brand?
A different brand may be considered only after checking membrane size, performance range, operating pressure, feedwater quality, recovery rate and permeate quality requirements. Final suitability should be confirmed against the existing SWRO system design.
What information is needed for a quote?
Please provide the existing membrane model, quantity, feedwater salinity or conductivity, application, operating pressure, recovery rate, required permeate quality, preferred lead time and delivery postcode where available.
Product Overview
Specifications
Operating Limits
Selecting HF, MR or HR
Typical Applications
Supply, Lead Time & Freight